17.4. signal
— Set handlers for asynchronous events¶
This module provides mechanisms to use signal handlers in Python. Some general rules for working with signals and their handlers:
A handler for a particular signal, once set, remains installed until it is explicitly reset (Python emulates the BSD style interface regardless of the underlying implementation), with the exception of the handler for
SIGCHLD
, which follows the underlying implementation.There is no way to 《block》 signals temporarily from critical sections (since this is not supported by all Unix flavors).
Although Python signal handlers are called asynchronously as far as the Python user is concerned, they can only occur between the 《atomic》 instructions of the Python interpreter. This means that signals arriving during long calculations implemented purely in C (such as regular expression matches on large bodies of text) may be delayed for an arbitrary amount of time.
When a signal arrives during an I/O operation, it is possible that the I/O operation raises an exception after the signal handler returns. This is dependent on the underlying Unix system’s semantics regarding interrupted system calls.
Because the C signal handler always returns, it makes little sense to catch synchronous errors like
SIGFPE
orSIGSEGV
.Python installs a small number of signal handlers by default:
SIGPIPE
is ignored (so write errors on pipes and sockets can be reported as ordinary Python exceptions) andSIGINT
is translated into aKeyboardInterrupt
exception. All of these can be overridden.Some care must be taken if both signals and threads are used in the same program. The fundamental thing to remember in using signals and threads simultaneously is: always perform
signal()
operations in the main thread of execution. Any thread can perform analarm()
,getsignal()
,pause()
,setitimer()
orgetitimer()
; only the main thread can set a new signal handler, and the main thread will be the only one to receive signals (this is enforced by the Pythonsignal
module, even if the underlying thread implementation supports sending signals to individual threads). This means that signals can’t be used as a means of inter-thread communication. Use locks instead.
The variables defined in the signal
module are:
-
signal.
SIG_DFL
¶ This is one of two standard signal handling options; it will simply perform the default function for the signal. For example, on most systems the default action for
SIGQUIT
is to dump core and exit, while the default action forSIGCHLD
is to simply ignore it.
-
signal.
SIG_IGN
¶ This is another standard signal handler, which will simply ignore the given signal.
-
SIG*
All the signal numbers are defined symbolically. For example, the hangup signal is defined as
signal.SIGHUP
; the variable names are identical to the names used in C programs, as found in<signal.h>
. The Unix man page for 〈signal()
〉 lists the existing signals (on some systems this is signal(2), on others the list is in signal(7)). Note that not all systems define the same set of signal names; only those names defined by the system are defined by this module.
-
signal.
CTRL_C_EVENT
¶ The signal corresponding to the Ctrl+C keystroke event. This signal can only be used with
os.kill()
.Availability: Windows.
버전 2.7에 추가.
-
signal.
CTRL_BREAK_EVENT
¶ The signal corresponding to the Ctrl+Break keystroke event. This signal can only be used with
os.kill()
.Availability: Windows.
버전 2.7에 추가.
-
signal.
NSIG
¶ One more than the number of the highest signal number.
-
signal.
ITIMER_REAL
¶ Decrements interval timer in real time, and delivers
SIGALRM
upon expiration.
-
signal.
ITIMER_VIRTUAL
¶ Decrements interval timer only when the process is executing, and delivers SIGVTALRM upon expiration.
-
signal.
ITIMER_PROF
¶ Decrements interval timer both when the process executes and when the system is executing on behalf of the process. Coupled with ITIMER_VIRTUAL, this timer is usually used to profile the time spent by the application in user and kernel space. SIGPROF is delivered upon expiration.
The signal
module defines one exception:
-
exception
signal.
ItimerError
¶ Raised to signal an error from the underlying
setitimer()
orgetitimer()
implementation. Expect this error if an invalid interval timer or a negative time is passed tosetitimer()
. This error is a subtype ofIOError
.
The signal
module defines the following functions:
-
signal.
alarm
(time)¶ If time is non-zero, this function requests that a
SIGALRM
signal be sent to the process in time seconds. Any previously scheduled alarm is canceled (only one alarm can be scheduled at any time). The returned value is then the number of seconds before any previously set alarm was to have been delivered. If time is zero, no alarm is scheduled, and any scheduled alarm is canceled. If the return value is zero, no alarm is currently scheduled. (See the Unix man page alarm(2).) Availability: Unix.
-
signal.
getsignal
(signalnum)¶ Return the current signal handler for the signal signalnum. The returned value may be a callable Python object, or one of the special values
signal.SIG_IGN
,signal.SIG_DFL
orNone
. Here,signal.SIG_IGN
means that the signal was previously ignored,signal.SIG_DFL
means that the default way of handling the signal was previously in use, andNone
means that the previous signal handler was not installed from Python.
-
signal.
pause
()¶ Cause the process to sleep until a signal is received; the appropriate handler will then be called. Returns nothing. Not on Windows. (See the Unix man page signal(2).)
-
signal.
setitimer
(which, seconds[, interval])¶ Sets given interval timer (one of
signal.ITIMER_REAL
,signal.ITIMER_VIRTUAL
orsignal.ITIMER_PROF
) specified by which to fire after seconds (float is accepted, different fromalarm()
) and after that every interval seconds. The interval timer specified by which can be cleared by setting seconds to zero.When an interval timer fires, a signal is sent to the process. The signal sent is dependent on the timer being used;
signal.ITIMER_REAL
will deliverSIGALRM
,signal.ITIMER_VIRTUAL
sendsSIGVTALRM
, andsignal.ITIMER_PROF
will deliverSIGPROF
.The old values are returned as a tuple: (delay, interval).
Attempting to pass an invalid interval timer will cause an
ItimerError
. Availability: Unix.버전 2.6에 추가.
-
signal.
getitimer
(which)¶ Returns current value of a given interval timer specified by which. Availability: Unix.
버전 2.6에 추가.
-
signal.
set_wakeup_fd
(fd)¶ Set the wakeup fd to fd. When a signal is received, a
'\0'
byte is written to the fd. This can be used by a library to wakeup a poll or select call, allowing the signal to be fully processed.The old wakeup fd is returned (or -1 if file descriptor wakeup was not enabled). If fd is -1, file descriptor wakeup is disabled. If not -1, fd must be non-blocking. It is up to the library to remove any bytes from fd before calling poll or select again.
When threads are enabled, this function can only be called from the main thread; attempting to call it from other threads will cause a
ValueError
exception to be raised.버전 2.6에 추가.
-
signal.
siginterrupt
(signalnum, flag)¶ Change system call restart behaviour: if flag is
False
, system calls will be restarted when interrupted by signal signalnum, otherwise system calls will be interrupted. Returns nothing. Availability: Unix (see the man page siginterrupt(3) for further information).Note that installing a signal handler with
signal()
will reset the restart behaviour to interruptible by implicitly callingsiginterrupt()
with a true flag value for the given signal.버전 2.6에 추가.
-
signal.
signal
(signalnum, handler)¶ Set the handler for signal signalnum to the function handler. handler can be a callable Python object taking two arguments (see below), or one of the special values
signal.SIG_IGN
orsignal.SIG_DFL
. The previous signal handler will be returned (see the description ofgetsignal()
above). (See the Unix man page signal(2).)When threads are enabled, this function can only be called from the main thread; attempting to call it from other threads will cause a
ValueError
exception to be raised.The handler is called with two arguments: the signal number and the current stack frame (
None
or a frame object; for a description of frame objects, see the description in the type hierarchy or see the attribute descriptions in theinspect
module).On Windows,
signal()
can only be called withSIGABRT
,SIGFPE
,SIGILL
,SIGINT
,SIGSEGV
, orSIGTERM
. AValueError
will be raised in any other case.
17.4.1. Example¶
Here is a minimal example program. It uses the alarm()
function to limit
the time spent waiting to open a file; this is useful if the file is for a
serial device that may not be turned on, which would normally cause the
os.open()
to hang indefinitely. The solution is to set a 5-second alarm
before opening the file; if the operation takes too long, the alarm signal will
be sent, and the handler raises an exception.
import signal, os
def handler(signum, frame):
print 'Signal handler called with signal', signum
raise IOError("Couldn't open device!")
# Set the signal handler and a 5-second alarm
signal.signal(signal.SIGALRM, handler)
signal.alarm(5)
# This open() may hang indefinitely
fd = os.open('/dev/ttyS0', os.O_RDWR)
signal.alarm(0) # Disable the alarm